Tube settlers (lamella clarifiers) for industrial water

Tube settlers (lamella clarifiers) for industrial water


Category:

Code: FS 41.50 / FS 41.80 / FS 41.84

The tube settlers (lamella clarifiers) for sedimentation are made by gluing or welding profiled PVC or rigid polypropylene obtained by extrusion. The tube settlers are made in different sizes and shapes depending on the requirements (the size of the basin in which are mounted). The specialist will determine the proper distance between plates, height and tilt of the tube settlers.

Usually, the height of the tube settlers is 1000 mm and the assembly inclination of the shaped plates is 55º or 60º.

Code

U.m.

FS 41.50

FS 41.80

FS 41.84

Distance between plates

[mm]

44

80

82

Sedimentation area at 60º inclination

[m2/m3]

11

6,25

Sedimentation area at 55º inclination

[m2/m3]

13

7

Height

[mm]

500 ÷ 2000

700 ÷ 2000

Standard height

[mm]

1000

1000 / 1500

Hydraulic radius

[mm]

15

28

26

Material

 –

PVC

PP

PVC

PVC

PP

Dry weight

[kg/m3]

80

50

55

62

35

Maximum operating temperature

°C

55

75

55

55

75

Dimension

[mm x mm x mm]

upon request


The tube settlers are made in various shapes: