Application: from the ground, by positioning the phase clamp on the third rail, followed by the tightening of the clamp on it. The phase clamp must be handled using an insulating stick corresponding to the voltage of the installation.
Components:
Packing: waterproof bag.
Related products:
– Multipurpose modular insulating stick type PMU 20-1 B/ba / PMU 20-1 B/baS
Technical characteristics: see the table above (last column – Subway)
Technical characteristics |
Value |
Earthing cable cross-section Sp (mm2) |
120 |
Nominal short-circuit current for t = 1s Isc (kA) |
30 |
Shock (peak) nominal current for t = 0,02 s Isd (kA) |
60 |
Test short-circuit current for t = 1s (kA) |
34,5 |
Test shock (peak) current for t = 0,02 s (kA) |
69 |
Power factor (according to SR EN 61230) |
2 |
Earthing cable length (m) |
1,5 |
Diameter of the conductor where the phase clamp can be applied |
40, 49, 60, R65 |
Type of rails |
40 type |
Components: