Cooling tower PMM type

Cooling tower PMM type


Category:

Mixed structure casing
Construction materials:

• hot-dip galvanized steel (internal and external support structure), sandwich panels in fibreglass of 22 mm thickness, top-plate/covering supports foot-loads
Characteristics:
• high thickness (5-7 mm) of the profile channels of which the structure is composed, hot-dip galvanized (600 g/m2) after fabrication
• internal and external surface protection of the panels with a gel-coat resistant to UV radiation, hot and cold water, abrasion caused by weathering and by chemicals
• non-corroding

Fibreglass sandwich panels means
• double wall of fibreglass laminate between which is interposed the expanded support material
• only the inside surface of the side wall is in contact with the water to be cooled
• good sound absorption effect on the internal falling water noise
• 2 completely removable side-walls on the opposite side of inlet water are included instandard supply

Gearbox and shaft driven axial fan
Construction materials:
• hot-dip galvanized steel (electric motor support), extruded aluminium alloy with propeller profi le(fan blades)
• the drive system is composed of a hollow shaft without intermediate supports with flexible “lamellar” joints in 316 stainless steel (on request a carbon-fibre shaft can be supplied)
• the fan stack is entirely manufactured infi breglass, with fl anged segments for easy on-siteassembly
Characteristics:
• high performance, low electrical power input
• electric motor is positioned outside of the humid air stream

Fill pack (or heat exchange surface)
Construction materials:
• self-extinguishing PVC
Characteristics:
• 20 mm wide flute (air/water channels), reinforced top layer, reduced fouling
• high air/water heat exchange efficiency.

NOTE: all the models can be transported in several factory pre-assembled sections (also in container), whilst their subsequent site assembly is extremely simple and rapid.

Dimensional elements:
A – Total height of tower
B, C – Length / Width of the cooling tower (horizontally)
D – Axis quota of inlet water pipe in tower towards the base of the tower
E- Diameter of water inlet pipe in the cooling tower
F- Diameter fan

PMM cooling tower without basin

Type

A
[mm]

B
[mm]

C
[mm]

D
[mm]

E
Ø

F
[mm]

20

4750

4350

3800+*

1500

2×6″

3060

25

5600

4350

3800+*

1500

2×8″

3060

30

6450

4350

3900+*

1500

2×8″

3600

35

5600

6525

4100+*

1500

3×8″

4500

40

6450

6525

4100+*

1500

3×8″

4500

60

8400

7200

5050+*

1500

3×8″

5700

* the height is estalished depending each project

1. Body
2. Basin (optional)
3. Fill pack (for heat exchange)
4. Lid with axial fan
5. Cooling water distribution system (provided with flanges)
6. Shutters
7. Inspection/visit window